Home   |    Theory Contents   |    AlPrg Contents   |    Name Index   |    Subject Index   |    Sitemap

Aluminum Production

On Aluminum Production Page you calculate the amount of aluminum produced by electrolysis. The input values are: number of pots (300), time period (1 year), current intensity (135 kA) and current efficiency (95 %). AlPrg uses Equ. 8 of the Mass Balance chapter to calculate the aluminum production (113·103 t) .

AlPrg calculates 113·103 t of aluminum (the input field is desactivated because it contains the output value) produced by 300 pots, in the time period of one year, with a current intensity of 135 kA and a current efficiency of 95 %. You change the values in the activated input fields with the keyboard or with the mouse wheel.

Time Period Units and Metal Quality, Production Factor Combo Boxes

You find on this page two combo boxes that handle the time period units and the metal quality, production factor. When you click on the button of the Time Period Units Combo Box you select in a drop down menu the units of the time period: minutes, hours, days, months and years.

Time Period Units Combo Box.

With this combo box you select the time period units.

+ large figure.

Metal Quality, Production Factor Combo Box.

With this combo box you change the impurity value of the produced aluminum or the value of the production factor.

+ larger figure.

AlPrg assumes that the pots produces 100 % pure aluminum i.e. the program calculates with the theoretical production factor. In this case the current efficiency takes care of eventual impurities in the pot metal.
You may however use your own impurity value or production factor. After pressing the button on the combo box you select the input type: metal quality or production factor. Afterwards you enter your value with the keyboard or mouse wheel.

Determination of the Current Efficiency and Current Intensity

You may want to calculate the current efficiency the other parameters (Number of Pots, Time Period Current Intensity and the Aluminum Production) being the input. You click twice with the mouse pointer into the input field of the current efficiency. The field becomes inactivated i.e. it contains the result of the calculation.
In the same way you click on the current intensity input field if you want to determine this value.

Determination of Current Efficiency.

AlPrg calculates the current efficiency. Input are Number of Pots, Time Period, Current Intensity and Aluminum Production.

+ large figure.

Determination of Current Intensity.

AlPrg calculates the current intensity. Input are Number of Pots, Time Period, Current Efficiency and Aluminum Production.

+ large figure.

Determination of the Time Period

If you calculate the time period the result normally is not an entire number. AlPrg shows the time period in years, months, weeks, days, hours and minutes corresponding to the real time period value. 

Determination of Time Period.

The time period is calculated with the Number of Pots, Current Intensity, Current Efficiency and Aluminum Production as input.

+ large figure.

Determination of the Number of Pots

The same happens if you calculate the number of pots, AlPrg shows the entire number (NPots = 305) and the real number (NPots = 305.04).

Determination of the Number of Pots.

With number of pots is calculated with the Time Period, Current Intensity, Current Efficiency and Aluminum Production as input.

+ large figure.